OXYGEN SENSORS

Technical information

Oxygen Sensor Anatomy / Construction

How does the Oxygen Sensor Work?

Oxygen Sensor Analysis

How to Test Oxygen Sensors

Technical information

How does the Oxygen Sensor Work?

Zirconia Sensor Cross SectionZirconia Sensors: An important property of the Zirconia element is that it can conduct oxygen ions above a temperature of about 350°C. When the sensor is fitted, the outside of the Zirconia element is exposed to the exhaust gas and the inside is in contact with reference air.

Both sides of the element are coated with a thin layer of platinum that act as electrodes and carry the sensors voltage signal from the Zirconia element to the lead wire. At operating temperature, oxygen ions are able to pass through the element and deposit a charge on the platinum electrode thus generating a voltage signal.

If the AFR is rich, a high signal voltage is generated across the electrodes due to the difference in oxygen concentration present across the two sides of the element. Conversely, if the AFR is lean, a low voltage is generated across the electrodes due to the small difference in oxygen content between exhaust gases and the reference air inside the sensor.

Zirconia Sensor Voltage vs. AFR GraphTitania Sensors: The Titania element in these sensors does not produce a voltage like the Zirconia element. The property of the Titania element which allows for the detection of oxygen in the exhaust gas is its electrical resistance. The electrical resistance of the Titania element changes according to the concentration of oxygen in the exhaust gas.

The ECU supplies a voltage to the Titania sensor which depending on the presence, or lack of oxygen in the exhaust gas, will vary its resistance consequently changing the voltage signal returned back to the ECU relating to a lean or rich AFR.

Due to their different properties Titania and Zirconia sensors should not be interchanged under any circumstance.